Select a different country or region to see content for your location.
United States
10:29:42 GMT+0000 (Coordinated Universal Time)


GE480-DO
Spherical plain bearing
Radial spherical plain bearing, requiring maintenance, sliding contact surface: steel/steel, DIN ISO 12240-1, dimension series C, open design
Frequently bought together

Main Dimensions & Performance Data
| d | 480 mm | Bore diameter bearing |
| D | 650 mm | Outside diameter bearing |
| B | 230 mm | Width Inner ring |
| Cr | 13.800.000 N | Basic dynamic load rating, radial |
| C0r | 53.100.000 N | Basic static load rating, radial |
| ≈m | 235,6 kg | Weight |
Mounting dimensions
| r1smin | 2 mm | Edge Spacing |
| r2smin | 5 mm | Edge Spacing |
| da max | 516 mm | Connection measure Inner ring |
| Da min | 536 mm | Housing Connection Diameter |
Dimensions
| C | 195 mm | Width Outer ring |
| dK | 565 mm | Ball diameter |
| α | 3,8 ° | Tilt angle |
| dOT | 0 mm | Bore diameter bearing, upper tolerance |
| dUT | -0,045 mm | Bore diameter bearing, lower tolerance |
| DOT | 0 mm | Outside diameter, upper tolerance |
| DUT | -0,075 mm | Outside diameter, lower tolerance |
| BOT | 0 mm | Width inner ring, upper tolerance |
| BUT | -0,45 mm | Width inner ring, lower tolerance |
| COT | 0 mm | Width outer ring, upper tolerance |
| CUT | -1,1 mm | Width outer ring, lower tolerance |
| Gr | 0,145 - 0,285 | Radial Clearance |
| Grmax | 0,285 mm | Radial clearance, maximum |
| Grmin | 0,145 mm | Radial clearance, minimum |
Temperature range
| Tmin | -60 °C | Operating temperature min. |
| Tmax | 200 °C | Operating temperature max. |
Operating conditions for bearing GE480-DO
In work for GE480-DO
CO₂e caused by friction during operation
Comprehensive information with immediate calculations of the CO2e emissions of our rotative products in various application scenarios.

Preset calculation parameters
Choose your calculations
Powered by Bearinx
Please add the remaining conditions.
CO₂e emissions
For Production info_outline
-
Rating life
Total Rating Life (Lh10)
-
Static safety (S0)
-
Your feedback helps us to continuously improve our product.